Silawarawet, K., Kaewchukul, P., & Saadprai, S. (2025). Heat Stroke Warning System Prototype for Athletes: A Pilot Study. Sensors, 25(2), 294. https://doi.org/10.3390/s25020294
Abstract

This research has developed a heat stroke warning system prototype for athletes utilizing the following sensors: DHT22, GY-906-BAA MLX90614, MAX30102. The device calculates the heat stroke risk and notifies users. The data is recorded, stored, displayed on a free-access website which graphs body temperature, ambient temperature, humidity, heart rate and heat stroke risk, and provides notifications for athletes engaged in outdoor activities. The researchers recorded sensors data (n = 1) for two sessions (12 min/session) in a closed room, at the sixth-minute marker, with an air conditioner activated to observe the changes observed by the sensors. For accuracy, the researchers employed Criterion-Related Validity, comparing sensor against standard equipment measurement. For reliability, we utilized Test-Retest Reliability, comparing sensor data from the first and second measurements. Accuracy and reliability were evaluated using the Pearson Correlation Coefficient, with significance set at p < 0.01. The DHT22 sensor demonstrates very high accuracy (r = 0.923) in ambient temperature and (r = 0.774) humidity measurements. It showed no significant reliability (r = 0.489) in temperature and (r = 0.185) humidity measurements. The GY-906-BAA MLX90614 sensor exhibited very high accuracy (r = 0.923) and reliability (r = 0.866) in body temperature measurements. The MAX30102 sensor lacked significant accuracy (r = 0.179) and reliability (r = 0.171) in heart rate measurements. The development of accuracy and reliability of sensors are important for preventing heat stroke in future applications.

Keywords: heat stroke, sensor, IoT, heat index, athletes
​URL: https://www.mdpi.com/3122718
Your browser does not support viewing this document. Click here to download the document.
Picture
Picture
0 Comments



Leave a Reply.

    Archives

    November 2025
    October 2025
    September 2025
    June 2025
    January 2025
    November 2023
    May 2023
    April 2023
    January 2023
    October 2022
    June 2022
    August 2021
    July 2021
    May 2021
    April 2021
    December 2020
    November 2020
    October 2020
    September 2020
    August 2020
    June 2020
    April 2020
    November 2019
    April 2019
    December 2018
    October 2018
    August 2017
    November 2016
    September 2016
    October 2013

    Categories

    All

    RSS Feed

We Would Love to Have You Visit Soon!


Hours

M-F: 7am - 7pm

Telephone

+66-(0)-2564-3001 ถึง 9 ต่อ 3247

Email

[email protected]